Skip to main content

Table 1 Precision and accuracy data for chloroquine and primaquine obtained by UPLC and HPLC methods

From: Simultaneous quantitation of chloroquine and primaquine by UPLC-DAD and comparison with a HPLC-DAD method

Validation parameters

UPLC

HPLC

Chloroquine

Primaquine

Chloroquine

Primaquine

Precision (CV%)

    

  Intra-day

1.10

1.04

1.10

0.31

  Inter-day

1.49

1.05

1.59

1.21

Accuracy (recovery %)

99.22

99.67

99.83

98.11