Skip to main content

Table 2 Temperature and carbon dioxide measurements before and after midnight

From: The effect of physical barriers under a raised house on mosquito entry: an experimental study in rural Gambia

Postion of logger

Temperature

 
 

21.00 h to 23.30 h

00.00 h to 07.00 h

 

Average (ºC)

Difference from control house

P

Average (ºC)

Difference from control house

P

Outdoors

26.2 (25.6–26.9)

  

26.2 (25.6–26.9)

  

Hut on the ground

28.9 (28.1–29.7)

Reference

 

26.6 (26.1–27.1)

Reference

 

Raised hut with open ground storey

28.9 (28.1–29.7)

0.98 (0.83–1.16)

0.832

26.5 (25.9–27.0)

0.90 (0.75–1.07)

0.222

Raised hut with air-permeable walls on the ground storey

28.8 (28.1–29.6)

0.94 (0.87–1.00)

0.061

26.5 (26.0–27.0)

0.91 (0.81–1.03)

0.138

Raised hut with solid walls on the ground storey

28.9 (28.1–29.7)

1.00 (0.95–1.06)

0.896

26.5 (26.0–27.1)

0.93 (0.86–1.00)

1.180

Postion of logger

Carbon dioxide

 
 

Average from 21.00 h to 23.30 h

Average from 00.00 h to 07.00 h

 

Average (ppm)

Difference from control house

P value

Average (ppm)

Difference from control house

P value

Outdoors

598 (548–648)

  

570 (537–602)

  

Hut on the ground

836 (782–891)

Reference

 

766 (725–806)

Reference

 

Raised hut with open ground storey

788 (736–840)

0.65 (0.40 to 1.08)

0.095

738 (704–771)

0.81 (0.73 to 0.89)

 < 0.001

Raised hut with air-permeable walls on the ground storey

798 (753–843)

0.53 (0.43 to 0.66)

 < 0.001

727 (693–761)

0.58 (0.44 to 0.77)

 < 0.001

Raised hut with solid walls on the ground storey

801 (758–844)

0.70 (0.45 to 1.11)

0.127

725 (694–755)

0.71 (0.58 to 0.89)

0.002

  1. General linearised modelling results, adjusted for hut position, sleeper pair and night
  2. CI confidence intervals